Abstract

Purpose: Nitinol, a nickel-titanium alloy, is a valuable material in the construction of interventional endoluminal devices because of its biocompatibility, super elasticity, high resiliency and shape memory. The possibility of nickel toxicity has been raised with devices constructed of Nitinol. Our investigation examines the long-term corrosive behavior of this alloy in experimental and biological environments. Methods: We performed three levels of study. Microscopic examination was made of 64 devices of various sizes, randomly selected from 240 Amplatzer® Septal Occluders that had been exposed to saline solution at 37°C for fourteen months. All samples were studied by electron microscopy ranging from 50 to 5000 times magnification. We also studied microscopically 3 Amplatzer® devices explanted 18–36 months after implantation in dogs, and 2 Amplatzer Septal Occluders removed from patients 18 months (cardiac transplant) and 19 months (died of causes unrelated to device placement) after implantation, which were examined grossly and by electron microscopy up to 5000 times magnification. We then measured the levels of nickel in the blood using inductive plasma mass spectroscopy in 19 patients with implanted Amplatzer® devices, making measurements before and 6 months after implantation. Results: Electron microscopy showed an intact titanium oxide layer with no evidence of corrosion in vitro and in vivo. One explanted device in direct contact with the platinum leads of a pacemaker for eighteen months showed minor pitting of the titanium oxide layer believed to be galvanic in nature. No wire fractures were found in vitro after cycle testing with 400 million cycles, nor in devices taken from the animals and humans. Biochemical studies showed no significant elevation of levels of nickel levels after implantation. Conclusion: Nitinol wire of Amplatzer® septal occlusion devices is resistant to corrosion when exposed to physiologic saline solution, and in experimental animals as well as humans. A device in contact with a platinum pacemaker electrode developed minimal pitting of the titanium oxide layer, believed to be galvanic in nature and of no structural or clinical significance. There is no increase of concentrations of nickel in the blood of patients who have received Amplatzer® nitinol devices. These favorable testing results reveal that nickel-titanium is an inert, corrosion resistant alloy.

Publisher

Cambridge University Press (CUP)

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Pediatrics, Perinatology, and Child Health

Cited by 31 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3