Comparison of 27-gauge and 25-gauge vitrectomy in the management of tractional retinal detachment secondary to proliferative diabetic retinopathy

Author:

Chen Po-LinORCID,Chen Yan-TingORCID,Chen San-NiORCID

Abstract

Objective To compare surgical outcomes between 27 and 25-gauge vitrectomy in proliferative diabetic retinopathy (PDR) with tractional retinal detachment (TRD) Methods This retrospective study was conducted to compare the intraoperative status, operation time, use of instruments, endotamponade substance, wound suture number, and iatrogenic break, between 27 and 25-gauge vitrectomy in 43 eyes afflicted by PDR with TRD. The post-surgical results, best-corrected visual acuity, intraocular pressure, recurrent vitreous haemorrhage, and re-operation rate were regularly followed up for 6 months. Results Patients in the 25 and the 27-gauge groups did not differ significantly in terms of pre-surgical conditions, such as age, gender, pre-existing glaucoma, best-corrected visual acuity (BCVA) and the severity of their TRD. The mean operation time was 56.7 minutes in the 27-gauge group and 63.7 minutes in the 25-gauge group (p = 0.94). There is significantly less use of micro forceps in the 27-gauge group (p = 0.004). No difference between micro scissors and chandelier usage were noted; neither was their difference in iatrogenic retinal breaks. Significantly fewer wound sutures were noted in the 27-gauge group (p < 0.001). The post-operative results revealed no significant difference in ocular hypertension, hypotony, BCVA improvement, recurrent vitreous haemorrhage and re-operation rate. Conclusions The 27-gauge vitrectomy system offers comparable surgical outcomes in PDR with TRD. The 27-gauge vitrectomy system is suitable for complicated retinal surgery.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference21 articles.

1. Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery;GY Fujii;Ophthalmology,2002

2. A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery;GY Fujii;Ophthalmology,2002

3. Transconjunctival sutureless 23-gauge vitrectomy;C Eckardt;Retina,2005

4. A 27-gauge instrument system for transconjunctival sutureless microincision vitrectomy surgery;Y Oshima;Ophthalmology,2010

5. Comparison of 25, 23 and 20-gauge vitrectomy;MJ Spirn;Curr Opin Ophthalmol,2009

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3