Prediction of extubation outcome in mechanically ventilated patients: Development and validation of the Extubation Predictive Score (ExPreS)

Author:

Baptistella Antuani RafaelORCID,Mantelli Laura Maito,Matte Leandra,Carvalho Maria Eduarda da Rosa Ulanoski,Fortunatti João Antonio,Costa Iury Zordan,Haro Felipe Gabriel,Turkot Vanda Laís de Oliveira,Baptistella Shaline Ferla,de Carvalho DiegoORCID,Nunes Filho João Rogério

Abstract

Despite the best efforts of intensive care units (ICUs) professionals, the extubation failure rates in mechanically ventilated patients remain in the range of 5%–30%. Extubation failure is associated with increased risk of death and longer ICU stay. This study aimed to identify respiratory and non-respiratory parameters predictive of extubation outcome, and to use these predictors to develop and validate an “Extubation Predictive Score (ExPreS)” that could be used to predict likelihood of extubation success in patients receiving invasive mechanical ventilation (IMV). Derivation cohort was composed by patients aged ≥18 years admitted to the ICU and receiving IMV through an endotracheal tube for >24 hours. The weaning process followed the established ICU protocol. Clinical signs and ventilator parameters of patients were recorded during IMV, in the end phase of weaning in pressure support ventilation (PSV) mode, with inspiratory pressure of 7 cm H2O over the PEEP (positive end expiratory pressure). Patients who tolerated this ventilation were submitted to spontaneous breathing trial (SBT) with T-tube for 30 minutes. Those who passed the SBT and a subsequent cuff-leak test were extubated. The primary outcome of this study was extubation success at 48 hours. Parameters that showed statistically significant association with extubation outcome were further investigated using the receiver operating characteristics (ROC) analysis to assess their predictive value. The area under the curve (AUC) values were used to select parameters for inclusion in the ExPreS. Univariable logistic regression analysis and ROC analysis were performed to evaluate the performance of ExPreS. Patients’ inclusion and statistical analyses for the prospective validation cohort followed the same criteria used for the derivation cohort and the decision to extubate was based on the ExPreS result. In the derivation cohort, a total of 110 patients were extubated: extubation succeeded in 101 (91.8%) patients and failed in 9 (8.2%) patients. Rapid shallow-breathing index (RSBI) in SBT, dynamic lung compliance, duration of IMV, muscle strength, estimated GCS, hematocrit, and serum creatinine were significantly associated with extubation outcome. These parameters, along with another parameter—presence of neurologic comorbidity—were used to create the ExPreS. The AUC value for the ExPreS was 0.875, which was higher than the AUCs of the individual parameters. The total ExPreS can range from 0 to 100. ExPreS ≥59 points indicated high probability of success (OR = 23.07), while ExPreS ≤44 points indicated low probability of success (OR = 0.82). In the prospective validation cohort, 83 patients were extubated: extubation succeeded in 81 (97.6%) patients and failed in 2 (2.4%) patients. The AUC value for the ExPreS in this cohort was 0.971. The multiparameter score that we propose, ExPreS, shows good accuracy to predict extubation outcome in patients receiving IMV in the ICU. In the prospective validation, the use of ExPreS decreased the extubation failure rate from 8.2% to 2.4%, even in a cohort of more severe patients.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3