The influence of corn trypsin inhibitor on the contribution of coagulation determinants to the Technoclone Thrombin Generation Assay (TGA) and the Calibrated Automated Thrombogram (CAT)

Author:

Touw Carolina E.ORCID,de Jong YpeORCID,van Hylckama Vlieg Astrid

Abstract

In thrombin generation (TG) assays, regarded as global coagulation tests, contact activation is considered a major problem which can be eliminated by adding Corn Trypsin Inhibitor (CTI). In previous studies, however, venous thrombosis risk prediction using TG assays did not improve after CTI addition. However, it is unknown whether CTI addition could help to detect subtle but relevant nuances in determinants of TG, making the assay more suitable to detect disturbances in the coagulation system. This study’s objective was to assess whether the addition of CTI is associated with a broader contribution of individual coagulation factors to the total amount of thrombin formed in Calibrated Automated Thrombogram (CAT) and Technoclone Thrombin Generation Assay (TGA). Thrombin generation was measured in 326 healthy individuals from THE VTE study at very low tissue factor concentrations, with and without addition of CTI prior to blood sampling. The influence of several coagulation factors on total amount of thrombin formed, i.e. area under the curve (AUC) or endogenous thrombin potential (ETP), was analysed using multiple linear regression with standardisation of all values resulting in Z-scores with 95% confidence intervals (95%CI). Association between coagulation factors and TG changed minimally after addition of CTI. Largest changes after CTI addition were found for following factors: for CAT: free protein S (from 0.00 (95%CI -0.12 to 0.12) to -0.29 (95%CI -0.43 to -0.15)) and protein S (from -0.05 (95%CI -0.18 to 0.08) to -0.21 (95%CI -0.37 to -0.05)); for TGA: antithrombin (from -0.11 (-0.23 to 0.02) to -0.19 (-0.30 to -0.07)), factor VIII (from 0.15 (0.03 to 0.27) to 0.24 (0.13 to 0.36)) and fibrinogen (from 0.12 (-0.01 to 0.26) to 0.19 (0.06 to 0.32)). In conclusion, there is no clear trend towards a broader contribution of coagulation factors in samples handled with CTI compared with those handled without CTI.

Funder

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference24 articles.

1. Thrombin Generation Assay and Its Application in the Clinical Laboratory;A. Tripodi;Clinical chemistry,2016

2. The measurement and application of thrombin generation;T. Baglin;British journal of haematology,2005

3. Assessment of thrombin generation: useful or hype?;M. Adams;Seminars in thrombosis and hemostasis,2009

4. Thrombin generation assays for global evaluation of the hemostatic system: perspectives and limitations;RCF Duarte;Revista brasileira de hematologia e hemoterapia,2017

5. Clinical measurement of thrombin generation by calibrated automated thrombography requires contact factor inhibition.;R Luddington;Journal of thrombosis and haemostasis: JTH,2004

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3