How to choose the intraocular lens power calculation formulas in eyes with extremely long axial length? A systematic review and meta-analysis

Author:

Li XiaoyuORCID,Wang Xiaodong,Liao XuanORCID

Abstract

Objective To evaluate the accuracy of 10 formulas for calculating intraocular lens (IOL) power in cataract eye with an axial length (AL) of more than 28.0 mm. Methods We searched scientific databases including PubMed, EMBASE, Web of Science and Cochrane Library for research published over the past 5 years, up to Sept 2023. The inclusion criteria were case series studies that compared different formulas (Barrett II, EVO, Kane, Hill-RBF, Haigis, Hoffer Q, Holladay 1, SRK/T, Holladay 1 w-k and SRK/T w-k), in patients with extremely long AL undergoing uncomplicated cataract surgery with IOL implantation. The mean difference (MD) of mean absolute error (MAE) and the odds ratio (OR) of both the percentage of eyes within ±0.50D of prediction error (PPE±0.50D) and the percentage of eyes within ±1.00D of prediction error (PPE±1.00D) among different formulas were pooled using meta-analysis. Results A total of 11 studies, involving 1376 eyes, were included to evaluate the 10 formulas mentioned above. Among these formulas, Barrett II, EVO, Kane, and Hill-RBF demonstrated significantly lower MAE values compared to SRK/T. Furthermore, Kane and Hill-RBF had lower MAE values than EVO. Additionally, Barrett II and Kane yielded significantly lower MAE values than Haigis while Hill-RBF showed significantly lower MAE values than Holladay 1. Moreover, Hill-RBF showed the highest values for both PPE±0.50D and PPE±1.00D, followed by Kane. Both EVO and Kane had higher values of PPE±0.50D and PPE±1.00D compared to Haigis and SRK/T. Conclusion The Wang-Koch adjusted formulas and new-generation formulas have shown potential for higher accuracy in predicting IOL power for cataract patients with extremely long AL compared to traditional formulas. Based on the current limited clinical studies, Hill-RBF and Kane formulas seem to be a better choice for eyes with extremely long AL.

Funder

Project of the National Natural Science Foundation of Sichuan Provincial Department of Science and Technology

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3