Comparative evaluation of iStent versus iStent inject W combined with phacoemulsification in open angle glaucoma

Author:

Morita ShuuORCID,Sakanishi YoshihitoORCID,Riyu Ikari,Watanabe Satoshi,Ebihara Nobuyuki

Abstract

Purpose The study aimed to compare the 12-month post-operative outcomes of iStent and iStent inject W (inject W), and the factors associated with their success in open-angle glaucoma. Methods This single-center, retrospective comparative case series evaluated the medical records of patients who underwent iStent (comprising 1 stent) or inject W (comprising 2 stents) implantation with cataract surgery for primary open-angle glaucoma and normal tension glaucoma between January 2019 and March 2022. The 12-month post-operative efficacy outcomes included intraocular pressure (IOP), glaucoma medications, and survival analysis of the probability of success. “Failure” was defined as any of the following conditions compared to baseline: 1) IOP elevation, 2) increased glaucoma medication, or 3) IOP decline not exceeding 20% when glaucoma medication scores were comparable, and 4) need for additional glaucoma surgery. The safety outcomes included intra- and post-operative adverse events and changes in the best-corrected visual acuity and visual field. Results The study comprised 55 eyes in the iStent and 105 in the inject W groups. At 12 months, treatment success was achieved in 66.0% of iStent and 78.4% of inject W eyes. The mean IOP was lower, and the percent reduction from baseline was equal in iStent-treated eyes (8.0% reduction, 14.8 mmHg to 13.7 mmHg, P<0.01) and inject W-treated eyes (11.9% reduction, 15.0 mmHg to 13.8 mmHg, P<0.01) (between-group comparison, P = 0.23). The mean medication burden decreased significantly from 2.5 to 1.1 for iStent (55.0% reduction, P<0.01) and 2.9 to 1.7 for iStent inject (46.8% reduction, P<0.01), with no significant differences between the two groups (P = 0.17). Both devices exhibited excellent safety. Conclusions Both devices significantly reduced IOP and glaucoma medication 12 months post-operatively. The outcome measures did not differ significantly between the two groups, and lower baseline IOP was predictive of surgical failure.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3