Validity and reliability of portable A-mode ultrasound in measuring body fat percentage: A systematic review with meta-analysis

Author:

Ferreira Luiz FernandoORCID,Silva Elirez Bezerra da,Bomfim Alexander Barreiros CardosoORCID

Abstract

The present Systematic Review with Meta-analysis study aimed to evaluate the validity and reliability of the Portable A-mode Ultrasound (P-US) for measuring body fat percentage (BF%). Only studies with participants of both genders which had assessed BF% using P-US compared to the reference standard were selected. Publications up until May 31, 2022 were searched in the MEDLINE, COCHRANE, Science Direct, Web of Science, LILACS, SciELO, PEDro, SPORT Discus, CINAHL and SCOPUS databases. QUADAS-2 was used to assess the risk of bias in the validity studies and QAREL was used for the methodological quality of reliability studies. The JAMOVI software program synthesized the results, from which the Pearson Correlation Coefficient (r) or the square root of the Multiple Linear Regression Determination Coefficient (R2) were extracted for the validity studies, and the Mean of Errors of the Bland-Altman Test (ME) and the Confidence Interval (95%CI) with Upper and Lower Limits for the reliability studies. A total of 13 studies were included, generating 26 results for the quantitative synthesis, 14 for validity and 12 for reliability. Regarding the validity results, a strong correlation was identified between the equipment (r = 0.870 [0.845–0.895], P<0.001), with moderate and true heterogeneity (I2 = 53.47%, P = 0.003), presenting publication bias. A small effect size was identified regarding the reliability results, overestimating the results due to chance between the devices (ME = 0.207 [-0.798–1.212], P = 0.686), with low heterogeneity also due to chance (I2 = 19.44%, P = 0.253), with no publication bias. All of the evaluated studies showed some violation of the instruments, confirming the high risk of bias and the low methodological quality. There is concern with heterogeneity for the validity results explained by the subgroups’ analysis. The P-US associated with anthropometric perimeters satisfactorily measures the BF% with samples greater than 100 participants, and males. The results in the reliability assessment show high agreement and high variability, greatly expanding the confidence interval, which should be viewed with reservations. This review received financial support from the Brazilian Air Force. The study was registered with PROSPERO under the number CRD42020166617.

Funder

Brazilian Air Force

Publisher

Public Library of Science (PLoS)

Reference49 articles.

1. Validade do teste de aptidão física do Exército Brasileiro como instrumento para a determinação das valências necessárias ao militar;AM Oliveira E de;Rev Educ Física,2005

2. Predictors of low physical fitness in a cohort of active-duty U.S. Air Force members;AS Robbins;Am J Prev Med,2001

3. Body Composition and Military Performance ‐ Many Things to Many People;K. Friedl;J Strength Cond Res,2012

4. Obesity classification in military personnel: A comparison of body fat, waist circumference, and body mass index measurements;KM Heinrich;Mil Med,2008

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3