Abstract
Purpose
To determine the diagnostic accuracy of the Xpert MTB/RIF assay in patients with smear-negative pulmonary tuberculosis (TB) and to assess clinical and CT characteristics of Xpert-negative pulmonary TB.
Material and methods
We retrospectively reviewed the records of 1,400 patients with suspected pulmonary TB for whom the sputum Xpert MTB/RIF assay was performed between September 1, 2014 and February 28, 2020. Clinical and CT characteristics of smear-negative pulmonary TB patients with negative Xpert MTB/RIF results were compared with positive results.
Results
Of 1,400 patients, 365 (26.1%) were diagnosed with pulmonary TB and 190 of 365 patients (52.1%) were negative for sputum acid-fast bacilli. The diagnosis of pulmonary TB was based on a positive culture, positive Xpert MTB/RIF or the clinical diagnoses of patients treated with an anti-TB medication. The sensitivity, specificity, positive predictive and negative predictive values of sputum Xpert MTB/RIF for smear-negative pulmonary TB were 41.1%, 100%, 100%, and 90.1%, respectively. Finally, 172 patients with smear-negative pulmonary TB who underwent chest CT within 2 weeks of diagnosis were included to compare Xpert-positive (n = 66) and Xpert- negative (n = 106) groups. Patients with sputum Xpert-negative TB showed lower positive rates for sputum culture (33.0% vs. 81.8%, p<0.001) and bronchoalveolar lavage culture (53.3% vs. 84.6%, p = 0.042) than in Xpert-positive TB. Time to start TB medication was longer in patients with Xpert-negative TB than in Xpert-positive TB (11.3±16.4 days vs. 5.0±8.7 days, p = 0.001). On chest CT, sputum Xpert-negative TB showed significantly lower frequency of consolidation (21.7% vs. 39.4%, p = 0.012), cavitation (23.6% vs. 37.9%, p = 0.045), more frequent peripheral location (50.9% vs. 21.2 p = 0.001) with lower area of involvement (4.3±4.3 vs. 7.6±6.4, p<0.001). Multivariate analysis revealed peripheral location (odds ratios, 2.565; 95% confidence interval: 1.157–5.687; p = 0.020) and higher total extent of the involved lobe (odds ratios, 0.928; 95% confidence interval: 0.865–0.995; p = 0.037) were significant factors associated with Xpert MTB/RIF-negative TB. Regardless of Xpert positivity, more than 80% of all cases were diagnosed of TB on chest CT by radiologists.
Conclusion
The detection rate of sputum Xpert MTB/RIF assay was relatively low for smear negative pulmonary TB. Chest CT image interpretation may play an important role in early diagnosis and treatment of Xpert MTB/RIF-negative pulmonary TB.
Publisher
Public Library of Science (PLoS)
Reference34 articles.
1. Global Tuberculosis Report. World Health Organization.2018. https://apps.who.int/iris/handle/10665/274453.
2. Sputum processing methods to improve the sensitivity of smear microscopy for tuberculosis: a systematic review;KR Steingart;Lancet Infect Dis,2006
3. Performance of the Xpert MTB/RIF assay for the diagnosis of pulmonary tuberculosis and rifampin resistance in a low-incidence, high-resource setting;JP Rice;PloS one,2017
4. Rapid drug susceptibility testing of Mycobacterium tuberculosis using conventional solid media;T Schaberg;Eur Respir J,1995
5. Diagnostic Standards and Classification of Tuberculosis in Adults and Children. This official statement of the American Thoracic Society and the Centers for Disease Control and Prevention was adopted by the ATS Board of Directors, July 1999. This statement was endorsed by the Council of the Infectious Disease Society of America, September 1999;Am J Respir Crit Care Med,2000