Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement

Author:

Ramsey DanielleORCID,Ramdharry Gita,Scoto Mariacristina,Muntoni FrancescoORCID,Wallace Amanda,

Abstract

The Revised Hammersmith Scale (RHS) for Spinal Muscular Atrophy (SMA) was designed as a psychometrically robust clinical outcome assessment to assess physical abilities of patients with type 2 and 3 SMA. The reliability properties of the RHS have not yet been reported. A prospective RHS reliability study was undertaken in a UK cohort of experienced neuromuscular paediatric Physiotherapists. Reliability testing was conducted via a virtual survey platform two weeks apart. Through the virtual platform participants scored videos of two RHS assessments, one of a child with SMA 2 and one of a child with SMA 3. Inter and intra-rater reliability was analysed using a type 3 Intraclass Correlation Coefficient (ICC). Intra-rater agreement was further analysed using Bland Altman (BA) Limits of Agreement (LOA) and plots. The acceptable inter and intra-rater variability was set as a change of ± 2 by the international team of expert physiotherapists who developed the RHS. Inter-rater agreement, n = 22 raters, type 3 ICC was 0.989 (95% CI 0.944 to 1.00), 97.7% of scores were within the acceptable limits of ± 2 points. Intra-rater agreement, n = 21 raters, type 3 ICC ranged from 0.922 to 1.0, with 97.6% of scores within the acceptable limits of ± 2 points. The mean SMA 2 intra-rater difference was -0.10 (-0.6 to 0.4), with lower LOA -2.24 and upper LOA +2.04. Intra-rater difference between tests for SMA 3 intra-rater difference was -0.05 (-0.6 to 0.5), with lower LOA -2.48 and upper LOA +2.38. Intra-rater scoring precision fell within BA agreement limits of ±2 points. The results demonstrate that the RHS is highly reliable when used by experienced UK physiotherapists, and variability of test scores regarding inter and intra-rater reliability was confirmed to lie within ±2 points.

Funder

National Institute for Health Research Biomedical Research Centre at Great Ormond Street Hospital for Children NHS Trust and University College London

SMA Trust

Biogen

Muscular Dystrophy UK

MRC Translational Research Centre at UCL and Newcastle

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference38 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3