Comparison of compensatory shoulder movements, functionality and satisfaction in transradial amputees fitted with two prosthetic myoelectric hooks

Author:

Touillet Amélie,Billon-Grumillier ConstanceORCID,Pierret JonathanORCID,Herbe Pierrick,Martinet Noël,Loiret Isabelle,Paysant Jean

Abstract

The functionalities of myoelectric hooks, such as whether they allow wrist movements, as well as the volume and design of the devices, may impact how fitted transradial amputees use their upper limbs. The aim of the current study was to compare two prosthetic myoelectric hooks in terms of compensatory shoulder movements, functionality and user satisfaction. This monocentric, randomized, controlled, cross-over trial evaluated eight transradial amputees fitted with two prosthetic myoelectric hooks, the Greifer and the Axon-Hook, during two consecutive periods. At the end of each period, shoulder abduction (mean and percentage of time with shoulder abduction > 60°) and manual dexterity were assessed using the Box and Blocks Test (BBT) on both sides, and satisfaction was assessed with the Evaluation of Satisfaction with Assistive Technology questionnaire. For each patient, data obtained with the BBT on the amputated side were compared with those obtained on the non-amputated side. Shoulder abduction was significantly higher with the Greifer (60.9°± 20.3°, p = 0.03) than with the Axon-Hook (39.8°± 16.9°) and also than with the NA side (37.6 ± 19.4°, p = 0.02). Shoulder abduction on the NA side (37.6 ± 19.4°) was close to that of the Axon-Hook (39.8°± 16.9°). The percentage of time spent with shoulder abduction > 60° during the BBT was higher with the Greifer than with the Axon-Hook or with the NA side (53.3 ± 34.4%, 17.6 ± 27.0% and 18.4 ± 34.9%, respectively), but the differences were not significant (p = 0.15). A significant strong negative correlation was found between shoulder abduction and wrist position with the Axon-Hook (r = -0.86; p < 0.01), but not with the Greifer. Manual dexterity and satisfaction did not differ significantly between the two devices. These results revealed compensatory movements, such as shoulder abduction in transradial amputees equipped with hooks, themselves influenced by the prosthetic device settings.

Funder

OTTOBOCK FRANCE

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3