Comparison of a hand-held high-end resolution infrared thermography (FLIR P640) and a smartphone infrared thermographic device (FLIR One) for the assessment of skin surface temperature after anaesthetising the median nerve in Healthy horses

Author:

Ferlini Agne GustavoORCID,Adamson Kellie,McGlinchey Leah,Kravchuk OlenaORCID,Santos LuizORCID,Schumacher John

Abstract

Accuracy of a median nerve block is normally assessed by testing skin sensitivity on the medial and dorsal aspects of fetlock and pastern. The present study evaluated subjective and objective analysis of skin surface temperature obtained with two different infrared (IR) thermography cameras (a high-end [FLIR P640] and a smartphone IR thermography device [FLIR One®]) before and after anaesthesia of the median nerve. Thermographic images were obtained at 0, 30, 60 and 90 minutes after performing a median nerve block with 2% mepivacaine hydrochloride. The subjective analysis of thermographic images using the FLIR P640 camera found assessors had >50% agreement for the presence of a nerve block (p<0.01) based on assessment of skin temperature within the expected dermatome of the median nerve. The objective analysis found skin temperature increases in the treated leg using the FLIR One® in the dorsal fetlock, dorsal pastern and medial pastern at 60 minutes, and the lateral pastern at 90 minutes (p<0.05). The treated leg, imaged using the FLIR P640 camera, had increases in skin temperature at the medial aspect of the fetlock at 60 minutes and lateral pastern at 90 minutes (p<0.05). Images obtained with the P640 camera had higher resolution and finer thermal detail. The images obtained with the FLIR One® camera had a wider temperature range with overall higher temperature measurements than the images obtained using the P640 camera (p<0.001). Skin temperatures in horses should be interpreted with caution when using the FLIR One® camera. Furthermore, the FLIR One® device detected an increase in skin surface temperature in both treated and non-treated legs and should not be used for assessment of a median nerve block. Infrared thermography appears to be useful for determining the presence of a high regional nerve block such as the median nerve block by observing increased temperatures of the skin surface after perineural anaesthesia. Further studies with a larger sample size as well as investigating the use of thermography for assessment of other regional nerve blocks are warranted.

Publisher

Public Library of Science (PLoS)

Reference18 articles.

1. Nerve blocks and lameness diagnosis in the horse.;S. Dyson;In Practice,1984

2. Duration of action of mepivacaine and lidocaine in equine palmar digital perineural blocks in an experimental lameness model;M Hoerdemann;Veterinary Surgery,2017

3. Effect of High Regional Nerve Blocks on the Thermographic Patterns in the Limbs of Horses.;J Schumacher;Thermology International,2012

4. Skin temperature measured by infrared thermography after ultrasound‐guided blockade of the sciatic nerve;F Van Haren;Acta Anaesthesiologica Scandinavica,2013

5. Instrumentation of Thermography and its Applications in Horses;L Yanmaz;Journal of Animal and Veterinary Advances,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3