Light and electron microscopic features of preclinical pseudoexfoliation syndrome

Author:

Suwan YaninORCID,Kulnirandorn Tuangporn,Schlötzer-Schrehardt Ursula,Wongchaya Sattawat,Petpiroon Purit,Supakontanasan Wasu,Tantraworasin Apichat,Teekhasanee Chaiwat

Abstract

PurposeThis study sought to explore the features of the anterior lens capsule in patients with preclinical pseudoexfoliation syndrome (pPEX) via light microscopy (LM) and transmission electron microscopy (TEM).DesignCross-sectional, prospective, and observational case series.MethodsWe recruited consecutive patients with and without pPEX who underwent routine cataract surgery at Ramathibodi Hospital, between April 2018 and November 2020. pPEX can be characterized by pigmented spoke-wheel deposition (P) on the anterior lens capsule, midperiphery cleft/lacunae (C), faint central disc present within the photopic pupil (D), white-spoke pattern (W) noted at the midperiphery, and a combination of at least two signs (Co). LM and TEM were used to examine anterior lens capsule specimens for the presence of characteristic pseudoexfoliation material (PXM). The features of the anterior lens capsule in pPEX explored via LM and TEM were recorded.ResultsThis study included a total of 96 patients (101 excised anterior lens capsules); among them, 34 (35 excised anterior lens capsules) exhibited pPEX signs (pPEX group) but 62 (66 excised anterior lens capsules) did not (control group). The patients had a mean age of 74 ± 7 (range, 58–89) years. LM and TEM revealed no definite PXM in any patient. In the pPEX group, LM analysis identified two capsule specimens with suspected PXM; PXM precursors were observed in 1 of the 34 excised capsule specimens analyzed via TEM. Furthermore, 39 eyes (59.09%) exhibited signs of true exfoliation syndrome (TEX) in LM analysis (12.82%, 25.64%, 10.26%, 10.26%, and 41.03% for patients exhibiting P, D, C, W, and Co, respectively). However, no TEX signs were observed in the control group. We found that the anterior lens capsules exhibiting C and D were significantly associated with TEX (odds ratio = 5.4 and 7.9; P = 0.007 and 0.004, respectively).ConclusionsLM analysis revealed no definite PXMs were detected in the excised anterior lens capsules, whereas TEM analysis showed PXM precursors in one specimen (2.94%). Notably, a significant association was observed between C and D signs and TEX.

Funder

Ramathibodi Foundation

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3