Is Anterior Guidance a Key Factor on Planning Implant Treatment for Free-End Missing in the Posterior Mandible?

Author:

Nagao Mitsuharu1,Masaki Chihiro1,Nakao Mihoko2,Ito Yoshinori2,Tsuka Shintaro1,Mukaibo Taro1,Kondo Yusuke1,Hosokawa Ryuji1

Affiliation:

1. Division of Oral Reconstruction and Rehabilitation, Kyushu Dental University, Graduate School, Fukuoka, Japan.

2. Brain Corporation, San Diego, Calif.

Abstract

To perform safe implant treatment, the anatomical structure and bone quality at implant placement sites are evaluated based on a patient's computerized tomography (CT) data, but there is no definite method to determine placement sites and the appropriate number of implants. The objective of this study was to investigate the influence of the number and arrangement of implants on the stress distribution in 3-unit posterior fixed partial dentures for the posterior mandible by mechanical analysis using the finite element method. Three-dimensional finite element analysis models were constructed from the CT data of a patient with missing mandibular teeth (Nos. 35, 36, 37). Implant placement was simulated under various conditions. Superstructures were connected and fixed with a titanium frame. As the loading conditions, 400 N vertical and lateral loads (45° on the lingual side and 45° on the buccal side) were applied to the upper areas of Nos. 35, 36, and 37, and the stress distribution and frame displacement were evaluated. When a vertical force was applied, no difference of the von Mises stress was noted among the 5 experimental conditions. When lateral force was applied from the lingual and buccal sides at 45°, the stress was higher than that induced by vertical force under all conditions, and it was especially high under mesial and distal cantilever conditions. When displacement of the titanium frame was measured, the displacement caused by lateral force was greater than that due to vertical force. In addition, comparison between long and short distal cantilever bridges revealed that displacement of the titanium frame tended to be smaller when the short cantilever was used. These findings suggested that the stress on peri-implant tissues and displacement of the titanium frame vary depending on the configuration and number of implants, with greater stress and more marked displacement of the titanium frame being induced by lateral force when the number of implants is reduced and a cantilever bridge is selected.

Publisher

American Academy of Implant Dentistry

Subject

Oral Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Letter to the Editor;Journal of Oral Implantology;2020-01-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3