Non-invasive measurements of arterial structure and function: repeatability, interrelationships and trial sample size

Author:

LIANG Yu-Lu1,TEEDE Helena1,KOTSOPOULOS Dimitra1,SHIEL Louise1,CAMERON James D.2,DART Anthony M.3,McGRATH Barry P.1

Affiliation:

1. Department of Medicine, Monash Medical Centre, Monash University, Clayton, Victoria 3168, Australia

2. Department of Biomedical Engineering, La Trobe University, Kingsbury Drive, Bundoora, Victoria 3083, Australia

3. Baker Medical Research Institute, Commercial Road, Prahran, Victoria 3181, Australia

Abstract

1. Repeatability of measurements of arterial compliance and flow-mediated dilation of the brachial artery has been infrequently reported, despite increasing use in interventional and risk-factor modification studies. Furthermore, little is known about the interrelationships of the various indices. The purposes of this study were to determine the repeatability and interrelationships of a range of arterial indices. 2. Fifty healthy volunteers, 20 men and 30 women, aged 20–70 (mean 46.5) years, were studied on two occasions, using an identical protocol, at a mean interval of 2.5 weeks. Tonometry, ultrasound and Doppler technique were used to measure the following: carotid wall intima-media thickness (IMT), total systemic artery compliance (SAC), arterial pulse wave velocity [PWV aorto-femoral (A-F), and femoral-dorsalis pedis (F-D)], carotid distensibility coefficient (DC) and carotid augmentation index (AI). Brachial flow-mediated dilation was measured in 30 subjects with analysis of diameter change for 4 min post ischaemia. 3. There were no systematic differences over the observed range of measurements for any of the reported parameters. Coefficients of variation were as follows: IMT 2.8%, SAC 9.2%, PWV(A-F) 3.2%, PWV(F-D) 5.0%, DC 10.0%, AI 1.3%. Brachial flow-mediated dilation curves were not different between visits; changes were maximum 60-s post ischaemia. All indices of arterial compliance were significantly correlated with age. The three different indices of central arterial compliance [SAC, PWV(A-F) and AI] were significantly correlated with carotid intima-media thickness. 4. Under controlled experimental conditions there was good repeatability of measurements of indices between sessions of both intrinsic and functional arterial mechanical properties (central and carotid arterial compliance, intima-media thickness and brachial flow-mediated dilation). Sample size tables for clinical trials using these indices are presented.

Publisher

Portland Press Ltd.

Subject

General Medicine

Cited by 211 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司