Pitch and Longitudinal Fluting Effects on the Primary Stability of Miniscrew Implants

Author:

Brinley Christine L.1,Behrents Rolf2,Kim Ki Beom3,Condoor Sridhar4,Kyung Hee-Moon5,Buschang Peter H.67

Affiliation:

1. a Private Practice, St Louis, Mo

2. b Professor and Chair, Department of Orthodontics, St Louis University, St Louis, Mo

3. c Assistant Professor, Department of Orthodontics, St Louis University, St Louis, Mo

4. d Assistant Professor, Department of Mechanical Engineering, St Louis University, St Louis, Mo

5. e Professor, Department of Orthodontics, Dental School, Kyungpook National University, Daegu, Korea

6. f Professor, Department of Orthodontics, Baylor College of Dentistry, Dallas, Tex

7. Corresponding author: Dr Buschang, Department of Orthodontics, Baylor College of Dentistry, 3302 Gaston Ave, Dallas, TX 75246 (PHBuschang@bcd.tamhsc.edu)

Abstract

AbstractObjective: To test the hypotheses that pitch and fluting have no effect on the primary stability of miniscrew implants (MSIs).Materials and Methods: Maximum placement torque and pullout strength of experimental MSIs were compared with those of control MSIs with the use of synthetic and cadaver bone. MSIs with 1.00 mm pitch were compared with those with 1.25 mm and 0.75 mm pitch; MSIs with three longitudinal flutes were compared with the same MSIs without flutes. A total of 60 MSIs (15 of each design) were evaluated with synthetic bone; a split-mouth cadaver model was used to compare the three experimental designs against the 1 mm control MSIs (total of 90 MSIs).Results: The synthetic bone model showed higher placement torque and pullout strength for the 0.75 pitch than for the 1.0 mm and 1.25 mm pitch MSIs, but differences were significant (P < .05) only for pullout strength. The cadaver model showed no significant differences in placement torque or pullout strength associated with pitch. Both synthetic and cadaver bone models showed that MSIs with flutes had significantly (P < .05) higher placement torque and pullout strength. Spearman correlations between placement torque and pullout strength were statistically significant for both synthetic (r = .504) and cadaver (r = .502) bone.Conclusion: Within limits, decreasing MSI pitch increases pullout strength, and fluting increases both placement torque and pullout strength.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

Cited by 50 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3