Maxillary Molar Distalization with Noncompliance Intramaxillary Appliances in Class II Malocclusion

Author:

Antonarakis Gregory Stylianos1,Kiliaridis Stavros2

Affiliation:

1. c Resident, Department of Orthodontics, Dental School, University of Geneva, Geneva, Switzerland

2. b Professor and Department Chair, Department of Orthodontics, Dental School, University of Geneva, Geneva, Switzerland

Abstract

Abstract Objective: To use published data to evaluate quantitatively the dental effects of noncompliance intramaxillary appliances in individuals with Class II malocclusion. Materials and Methods: A literature search was carried out identifing 13 prospective or retrospective clinical studies matching inclusion criteria. Only appliances with conventional anchorage designs were considered for the review. The data provided in these publications were grouped and analyzed in terms of molar distalization, tipping and vertical movements, and incisor and premolar mesialization, tipping, and vertical movements. Results: Maxillary first molars showed distal crown movement and tipping greater than the mesial crown movement and tipping shown by incisors and premolars. Vertical movements of incisors and premolars were in general extrusive, but molars were intrusive or extrusive, depending on the study and the type of appliance used. Appliances that acted palatally seemed to display a smaller distal tipping movement, as well as smaller incisor and premolar mesial tipping movements, when compared with those that acted buccally. Friction-free appliances, namely the pendulum, produced a large amount of mesiodistal movement and tipping, if no therapeutic uprighting activation was applied. Conclusions: Noncompliance intramaxillary molar distalization appliances all act by distalizing molars with a concomitant and unavoidable loss of anchorage, as revealed by incisor and premolar mesial movement. Buccal acting and palatal acting appliances demonstrate almost similar results, with palatal acting appliances showing less tipping. Friction-free palatal acting appliances appear to produce better molar distalizing effects, but with a concomitant notable loss of anchorage.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3