A new flash-free orthodontic adhesive system: A first clinical and stereomicroscopic study

Author:

Foersch Moritz1,Schuster Christian2,Rahimi Roman K.3,Wehrbein Heinrich4,Jacobs Collin5

Affiliation:

1. Research Fellow, Department of Orthodontics and Dentofacial Orthopedics, University Mainz Medical Center Mainz, Germany.

2. Dental student, School of Dentistry, University Mainz Medical Center, Mainz, Germany.

3. Resident, Research Fellow, Department of Oral and Maxillofacial Surgery, University Mainz Medical Center, Mainz, Germany.

4. Professor and Chair, Department of Orthodontics and Dentofacial Orthopedics, University Mainz Medical Center, Mainz, Germany.

5. Assistant Professor, Department of Orthodontics and Dentofacial Orthopedics, University Mainz Medical Center, Mainz, Germany.

Abstract

ABSTRACT Objective:  To analyze the clinical and laboratory properties of the recently introduced APC flash-free orthodontic adhesive. Material and Methods:  After bonding of 80 brackets on human teeth (group A: APC flash-free adhesive n  =  40, group B: APC Plus adhesive n  =  40), the following measurements were recorded: time for bonding, stereomicroscopic evaluation of excess adhesive, color penetration (methylene blue, 0.5%/24 h), and Adhesive Remnant Index (ARI) score after debonding. Results:  The time needed for bonding differed significantly between the two groups (A: 19.5 s/tooth vs B: 33.8 s/tooth). The adhesive excess, which was metrically measured from the bracket edge, ranged from 166.27 µm to 81.66 µm (group A) and 988.53 µm to 690.81 µm (group B). After methylene coloration in group A, 52 of 80 measurements showed discoloration on the bracket-adhesive and/or adhesive-enamel interface, while for group B, 78 of 80 were coloration positive. The ARI scores did not differ, with an average ARI score of 2.0 for group A and 2.8 for group B. Conclusion:  The flash-free adhesive significantly reduced the time needed for the bonding process. The excess resin expanded 0.16 to 0.08 mm over the bracket margin. The new technology seems to facilitate a smooth and sufficient marginal surface of the adhesive, which clinically might improve reduction of plaque accumulation.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

Cited by 38 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3