Cytotoxicity of Two Autopolymerized Acrylic Resins Used in Orthodontics

Author:

Siqueira Gonçalves Tatiana1,Minghelli Schmitt Virgínia2,Thomas Melissa3,Lopes de Souza Maria Antonieta4,Macedo de Menezes Luciane5

Affiliation:

1. a Postgraduate (MS) student, Department of Orthodontics, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil

2. b Professor, Biomedical Research Institute, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil

3. c Graduate PhD student, Molecular Biology Laboratory, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil

4. d Professor, Micromorphology Laboratory, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil

5. e Professor, Department of Orthodontics, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil

Abstract

Abstract Objective: To test in vitro the null hypothesis that the toxic effect of different acrylic resins used in orthodontics cannot be reduced when a prior elution is performed. Materials and Methods: Three established cell lines were used (HeLa, NIH3T3, and Hep2) and cultured under standard conditions. Resin segments were immersed in a culture medium and left to elute for 24 and 48 hours. Cells were exposed to medium containing eluates for 24 or 48 hours. The 3-(4,5 dimethyl-2-thiazolyl)-2.5-diphenyl-2H-tetrazolium bromide (MTT) assay was used as the cytotoxicity test. Control cells contained standard medium with no eluate. Analysis of variance and Tukey test were used for statistical analysis. Results: Fibroblastic viability was not affected when the elution time was 24 hours, but treatments showed higher cell viability than controls when the elution time was 48 hours. When left to elute for 24 hours, both resins had a cytotoxic effect on epithelial cells, but this effect was not observed when the elution time was 48 hours. Conclusions: The hypothesis was rejected as both tested materials showed lower cytotoxic effect when treated with 48-hour elutes compared with 24-hour elutes, which indicates that a longer elution time reduces resin toxicity.

Publisher

The Angle Orthodontist (EH Angle Education & Research Foundation)

Subject

Orthodontics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3