A Comparison of ONTRAK TESTCUP™, Abuscreen ONTRAK®, Abuscreen ONLINE®, and GC/MS Urinalysis Test Results

Author:

Crouch DJ1,Cheever ML2,Andrenyak DM3,Kuntz DJ4,Loughmiller DL5

Affiliation:

1. Pharmacology and Toxicology Center for Human Toxicology University of Utah 1 Assistant Director, Center for Human Toxicology and Research assistant professor ,   490 Biomedical Polymens Building Salt Lake City, Utah84092

2. Center for Human Toxicology, University of Utah 2 Laboratory Technician , respectively, , Salt Lake City, Utah .

3. Center for Human Toxicology, University of Utah 3 Assistant Director , respectively, , Salt Lake City, Utah .

4. Workplace Drug Testing Division, Northwest Toxicology, Inc. 4 Laboratory Director , respectively, , 1141 E. 3900 South, Salt Lake City, Utah .

5. Workplace Drug Testing Division, Northwest Toxicology, Inc. 5 Operations Manager , respectively, , 1141 E. 3900 South, Salt Lake City, Utah .

Abstract

Abstract This study was designed to compare results obtained from two separate on-site drug testing kits (ONTRAK TESTCUP and Abuscreen ONTRAK) with those obtained from laboratory based immunoassay and GC/MS. Abuscreen ONLINE immunoassay was used to select 250 negative samples and 100 presumptive-positive samples each for cocaine/metabolites, opiates and cannabinoids. Presumptive-positive samples were selected if the immunoassay response was ⩾300 ng/mL for cocaine/metabolites (BZE), ⩾300 ng/mL for opiates or ⩾50 ng/mL for cannabinoids (THC-COOH). GC/MS was used to confirm that each selected sample contained ⩾150 ng/mL BZE, ⩾300 ng/mL morphine/codeine or ⩾15 ng/mL THC-COOH. TESTCUP results had a 100% agreement with GC/MS and a >99% agreement with ONLINE when testing negative samples. The agreement between TESTCUP and ONLINE results for samples containing opiates was 100%. Results of testing samples containing BZE with TESTCUP demonstrated a 98% agreement with both GC/MS and ONLINE. Both discrepant samples contained BZE at concentrations ⩽300 ng/mL. The least agreement between TESTCUP and ONLINE results was found when testing samples containing THC-COOH. The agreement with ONLINE and GC/MS was 92% and all discrepant samples had GC/MS determined THC-COOH concentrations less than 50 ng/mL. A 100% agreement was obtained between expected and recorded TESTCUP results for QC samples fortified to contained BZE, morphine or THC-COOH at concentrations within 120% of the screening cutoffs. ONTRAK had a 100% agreement with both GC/MS and ONLINE when testing negative samples and samples that contained opiates. ONTRAK had a 91% agreement with GC/MS and ONLINE for testing of samples that contained BZE. The least agreement between ONTRAK and ONLINE results was found when testing samples that contained THC-COOH. The agreement was 89%, however, all discrepant samples contained GC/MS concentrations of THC-COOH less that the 50 ng/mL cutoff. With ONTRAK, a 100% agreement was obtained between expected and recorded results on QC samples that contained morphine or THC-COOH and a 97.7% agreement was obtained between expected and recorded results on QC samples that contained BZE.

Publisher

ASTM International

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.7亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2025 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3