Heat Loss Optimization of a Building with Different Window to Wall Area Ratios

Author:

Koyun Tansel1ORCID,Koc Ersin2ORCID,Akcay Ismail Hakki3ORCID,Kent Emin Fuad4ORCID

Affiliation:

1. Department of Mechanical Engineering, Süleyman Demirel University 1 , Isparta, 32260, Turkey (Corresponding author), e-mail: tanselkoyun@sdu.edu.tr , ORCID link for author moved to before name tags https://orcid.org/0000-0002-5625-2413

2. Mechanical Engineering 2 , Antalya, 07050, Turkey , ORCID link for author moved to before name tags https://orcid.org/0000-0002-7348-0805

3. Department of Mechanical Engineering, Süleyman Demirel University 3 , Isparta, 32260, Turkey , ORCID link for author moved to before name tags https://orcid.org/0000-0002-9487-3624

4. Department of Mechanical Engineering, Istanbul Technical University 4 , Inonu Cad. No. 87 Gumussuyu, Istanbul, 34469, Turkey , ORCID link for author moved to before name tags https://orcid.org/0000-0002-5569-317X

Abstract

Abstract The types of glass and exterior walls and the window-to-wall ratio (WWR) on building façades play a major role in heat losses that occur in every type of building, residential or commercial. The opaque and transparent surfaces of buildings have an important role in terms of both energy losses and energy gains. Windows are the parts of the building envelope where heat losses mostly occur. As the WWR increases on the façades of a building, heat losses increase, but heat gains from solar energy also increase, which assists in free heating of the building. In this study, a detached residential building located in Antalya, Turkey, a province with hot–humid climatic conditions, has been examined. A series of simulations were carried out to detect the effects of WWRs and different glass, frame, and exterior wall types on heat losses of the building. The heat loss values obtained from these simulations were processed by using a special mechanical installation calculation software. Simulations were performed for apartment rooms with levels of WWR ranging from 30 to 60 % of the wall areas facing the façade. In order to minimize heat loss, double-pane glass (or double-glazed glass) was used instead of single-pane glass. The aim of this study was to find the optimum value in terms of applicability and economy. The optimum value was calculated by minimization according to both the linear graphical method and the dual simplex optimization method. The values found in both methods were compared and interpreted. It is believed that the optimized glass, frame, joinery, and exterior wall parameters, which are influential to the energy performance of the building, will make a positive contribution to the architectural design phase in addition to improving the energy efficiency of existing buildings.

Publisher

ASTM International

Reference35 articles.

1. Study on the Influence of Window-Wall Ratio on the Energy Consumption of Nearly Zero Energy Buildings;Feng;Procedia Engineering,2017

2. Thermal Insulation Requirements for Buildings, TS 825 (Ankara, Turkey: Turkish Standards Institution, 2013).

3. Energy Saving by Thermal Insulation on Exterior Walls and Problems in Details (Examples from Konya);Kocu,2010

4. Insulation Glass Combinations Used in Facade Systems;Ilhan,2005