Performance evaluation of a novel platelet count parameter, hybrid platelet count, on the BC-780 automated hematology analyzer

Author:

Prompetchara Eakachai1ORCID,Parnsamut Chalisa1,Chirapanuruk Angkana2,Ketloy Chutitorn1ORCID

Affiliation:

1. Department of Laboratory Medicine, Faculty of Medicine , Chulalongkorn University , Bangkok , Thailand

2. Division of Laboratory Medicine , King Chulalongkorn Memorial Hospital , Bangkok , Thailand

Abstract

Abstract Objectives Automated hematology analysis is expected to improve the performance of platelet counting. We evaluated the performance of a new platelet counting, hybrid (PLT-H) and also impedance (PLT-I) and optical (PLT-O) on the BC-780 automated hematology analyzer compared to the international reference method (IRM) in blood samples with thrombocytopenic and platelet interference. Methods The basic platelet count performance of the BC-780 automated hematology analyzer was evaluated according to the requirements of the Clinical Laboratory and Standards Institute (CLSI) Document H26-A2. Additionally, the thrombocytopenic (low PLT count) blood samples and the platelet interference blood samples including fragmented red blood cells (RBCs), microcytes or small RBCs, and giant platelets were determined with the BC-780 hematology analyzer compared to the IRM. Results Blank counting and the carry-over contamination rate of platelet count using the BC-780 both met the manufacturers’ claim. For both 123 thrombocytopenic and 232 platelet interference blood samples (72 fragmented RBCs, 91 microcytes and 51 giant platelets), all three platelet counting methods exhibited high comparability with the IRM (the lowest correlation (r)=0.916). Interestingly, the comparability of PLT-H (r=0.928–0.986) with the IRM was better than that of PLT-I (r=0.916–0.979). Conclusions The performance of PLT-H in the BC-780 met the manufacturer’s specifications. PLT-H exhibits better reproducibility than did PLT-I, correlates well with the PLT-O for thrombocytopenic samples and demonstrates good anti-interference ability. PLT-H counting is therefore recommended as a zero-cost alternative platelet counting method for platelet interference samples in clinical settings.

Funder

the Quality Improvement Fund grant from King Chulalongkorn Memorial Hospital

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3