The correlation of urea and creatinine concentrations in sweat and saliva with plasma during hemodialysis: an observational cohort study

Author:

Adelaars Sophie123ORCID,Konings Constantijn J.A.M.4,Cox Lieke5,Boonen Eva6,Mischi Massimo1,Bouwman R. Arthur12,van de Kerkhof Daan37

Affiliation:

1. Department of Electrical Engineering, Signal Processing Systems , Eindhoven University of Technology , Eindhoven , The Netherlands

2. Department of Anesthesiology , Catharina Hospital Eindhoven , Eindhoven , The Netherlands

3. Clinical Laboratory, Catharina Hospital Eindhoven , Eindhoven , The Netherlands

4. Department Internal Medicine and Kidney Diseases , Catharina Hospital Eindhoven , Eindhoven , The Netherlands

5. Royal Philips , Eindhoven , The Netherlands

6. Department of Anesthesiology and Intensive Care Medicine , General Hospital Turnhout , Turnhout , Belgium

7. Department of Biomedical Engineering, Chemical Biology , Eindhoven University of Technology , Eindhoven , The Netherlands

Abstract

Abstract Objectives Urea and creatinine concentrations in plasma are used to guide hemodialysis (HD) in patients with end-stage renal disease (ESRD). To support individualized HD treatment in a home situation, there is a clinical need for a non-invasive and continuous alternative to plasma for biomarker monitoring during and between cycles of HD. In this observational study, we therefore established the correlation of urea and creatinine concentrations between sweat, saliva and plasma in a cohort of ESRD patients on HD. Methods Forty HD patients were recruited at the Dialysis Department of the Catharina Hospital Eindhoven. Sweat and salivary urea and creatinine concentrations were analyzed at the start and at the end of one HD cycle and compared to the corresponding plasma concentrations. Results A decrease of urea concentrations during HD was observed in sweat, from 27.86 mmol/L to 12.60 mmol/L, and saliva, from 24.70 mmol/L to 5.64 mmol/L. Urea concentrations in sweat and saliva strongly correlated with the concentrations in plasma (ρ 0.92 [p<0.001] and 0.94 [p<0.001], respectively). Creatinine concentrations also decreased in sweat from 43.39 μmol/L to 19.69 μmol/L, and saliva, from 59.00 μmol/L to 13.70 μmol/L. However, for creatinine, correlation coefficients were lower than for urea for both sweat and saliva compared to plasma (ρ: 0.58 [p<0.001] and 0.77 [p<0.001], respectively). Conclusions The results illustrate a proof of principle of urea measurements in sweat and saliva to monitor HD adequacy in a non-invasive and continuous manner. Biosensors enabling urea monitoring in sweat or saliva could fill in a clinical need to enable at-home HD for more patients and thereby decrease patient burden.

Funder

Catharina Research Fund

Penta Program

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3