Performance evaluation of SARS-CoV-2 antigen detection in the post-pandemic era: multi-laboratory assessment

Author:

Chen Yuqing123,Feng Lei123,Han Yanxi13,Zhao Zihong134,Diao Zhenli123,Huang Tao123,Ma Yu123,Feng Wanyu123,Li Jing123,Li Ziqiang123,Liu Cong123,Chang Lu123,Li Jinming1235,Zhang Rui1235

Affiliation:

1. National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology , Beijing , P.R. China

2. National Center for Clinical Laboratories, Chinese Academy of Medical Sciences & Peking Union Medical College , Beijing , P.R. China

3. Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital , Beijing , P.R. China

4. Peking University Fifth School of Clinical Medicine , Beijing , P.R. China

5. National Center for Clinical Laboratories, Beijing Hospital , Beijing , P.R. China

Abstract

Abstract Objectives Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen detection is an indispensable tool for epidemic surveillance in the post-pandemic era. Faced with irregular performance, a comprehensive external quality assessment (EQA) scheme was conducted by the National Center for Clinical Laboratories (NCCL) to evaluate the analytical performance and status of SARS-CoV-2 antigen tests. Methods The EQA panel included ten lyophilized samples containing serial 5-fold dilutions of inactivated SARS-CoV-2-positive supernatants of the Omicron BA.1 and BA.5 strains and negative samples, which were classified into “validating” samples and “educational” samples. Data were analyzed according to qualitative results for each sample. Results A total of 339 laboratories in China participated in this EQA scheme, and 378 effective results were collected. All validating samples were correctly reported by 90.56 % (307/339) of the participants and 90.21 % (341/378) of the datasets. The positive percent agreement (PPA) was >99 % for samples with concentrations of 2 × 107 copies/mL but was 92.20 % (697/756) for 4 × 106 copies/mL and 25.26 % (382/1,512) for 8 × 105 copies/mL samples. Colloidal gold was the most frequently used (84.66 %, 320/378) but showed the lowest PPAs (57.11 %, 1,462/2,560) for positive samples compared with fluorescence immunochromatography (90 %, 36/40) and latex chromatography (79.01 %, 335/424). Among 11 assays used in more than 10 clinical laboratories, ACON showed a higher sensitivity than other assays. Conclusions The EQA study can help to validate whether it’s necessary to update antigen detection assays for manufacturers and provide participants with information about the performance of assays to take the first step toward routine post-market surveillance.

Funder

the National Key Research and Development Program of China

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3