When results matter: reliable creatinine concentrations in hyperbilirubinemia patients

Author:

Roelofsen-de Beer Roseri J.A.C.,van Zelst Bertrand D.,Vroling Aram B.,de Rijke Yolanda B.,Ramakers Christian

Abstract

Abstract Background Failure to report a creatinine concentration, especially in icteric patients who are eligible for a liver transplant, can result in a life-threatening situation. We assessed the influence of bilirubin interference on several creatinine assays and investigated ways to circumvent icteric interference without interfering with our normal automated sample logistics. Methods Using icteric patient sera (total bilirubin >255 μmol/L) we determined creatinine concentrations using an enzymatic and Jaffé assay (Roche Diagnostics) in both normal (i.e. undiluted) and decreased mode (i.e. diluted) as well as an enzyme-coupled amperometric assay on a Radiometer ABL837 FLEX analyzer. Creatinine concentrations from the five methods were compared with an in-house developed LC-MS/MS method. Passing and Bablok (proportional and constant bias) as well as difference plot parameters (bias and 95% limits of agreement [LoA]) were calculated. Interferograph-based regression analysis of the enzymatic and Jaffé results was used to investigate if such an approach could be used to report corrected creatinine concentrations in icteric patient sera. Results In icteric patient sera the enzyme-coupled amperometric assay was hardly influenced by icteric interference as shown by a difference plot bias of −1.5% (95% LoA −11.6 to +8.5%). The undiluted Jaffé method had a bias of −1.4% with a very broad 95% LoA (−35.1 to +32.2%) emphasizing the poor specificity of this method. The undiluted enzymatic method had the largest bias (−13.4%, 95% LoA −35.8 to +9.0%). Diluting sera in the enzymatic method did not improve the bias (−10.5%, 95% LoA −25.4 to 4.4%), while diluting the Jaffé method resulted in a bias increase (+11.4%, 95% LoA −14.7 to 37.5%). Using interferograph-based regression analysis we were able to reliably correct enzymatic creatinine concentrations in 97 out of 100 icteric patient sera. Conclusions Analytically, quantifying creatinine in icteric sera using the Radiometer ABL837 FLEX analyzer is the method of choice within our laboratory. However, not all laboratories are equipped with this method and even if available, the limited number of highly icteric patient sera makes this method costly. For those laboratories using the Roche enzymatic method, mathematically correcting an icteric creatinine concentration using an interferograph based on an LC-MS/MS reference method is a suitable alternative to report reliable creatinine results in icteric patients.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3