A possible cause of the variable detectability of macroprolactin by different immunoassay systems

Author:

Hattori Naoki,Aisaka Kohzo,Shimatsu Akira

Abstract

AbstractMacroprolactinaemia is a major cause of hyperprolactinaemia. The detectability of macroprolactin varies widely among different immunoassay systems, but the causes are not fully known. This study aimed to identify the factors influencing the detectability of macroprolactin by immunoassay systems.The study included 1544 patients who visited an obstetric and gynaecological hospital. Macroprolactinaemia was screened using the polyethylene glycol (PEG) method and confirmed using gel filtration chromatography and the protein G method. The prolactin (PRL) values determined by enzyme immunoassay (EIA) were compared with those of a chemiluminescence immunoassay system (Centaur) that is known to cross-react the least with macroprolactin.Macroprolactinaemia was found in 62 of 1544 patients (4.02%) who visited an obstetric and gynaecological hospital. The ratio of EIA-determined total PRL to free PRL in the supernatant after PEG precipitation was significantly elevated in all 62 serum samples with macroprolactin compared to those in 1482 serum samples without macroprolactin. In contrast, the ratio of Centaur-determined total PRL to free PRL was significantly elevated in 32 serum samples (group 1) and was within the normal range in 30 (group 2) of 62 serum samples with macroprolactin. The prevalence of non-IgG-type macroprolactin was significantly higher in group 1 than in group 2. Centaur diagnosed hyperprolactinaemia less frequently than EIA (n=2 vs. 16) in 62 patients with macroprolactinaemia. Those two hyperprolactinaemic patients diagnosed by Centaur had non-IgG-type macroprolactin.Macroprolactinaemia was present in 4% of patients visiting an obstetric and gynaecological hospital. The nature of macroprolactin (IgG-type or non-IgG-type) may partly explain why macroprolactin detectability varies among different immunoassay systems.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3