Determination of reference ranges for automated erythrocyte and reticulocyte parameters in healthy adults

Author:

Fırat Oğuz Esra1ORCID,Falay Mesude2,Ercan Karadağ Müjgan3ORCID,Uzdoğan Esma Andaç4ORCID,Akbulut Emiş Deniz4,Özet Gülsüm5,Turhan Turan6

Affiliation:

1. Department of Biochemistry , TC Saglik Bakanligi Ankara Numune Egitim ve Arastirma Hastanesi , Ankara , Turkey

2. Department of Hematology , TC Saglik Bakanligi Ankara Numune Egitim ve Arastirma Hastanesi , Ankara , Turkey

3. Department of Biochemistry, Faculty of Medicine , Afyonkarahisar Health Sciences University , Afyonkarahisar , Turkey

4. Department of Clinical Biochemistry , Ankara City Hospital , Ankara , Turkey

5. Department of Adult Hematology , Ministry of Health Ankara City Hospital , Ankara , Turkey

6. Department of Clinical Biochemistry , Ministry of Health Ankara City Hospital , Ankara , Turkey

Abstract

Abstract Objectives Recent advances in hematology analyzers have enabled to improve the reliability in the results and also provided additional hematological parameters. In the present study, we aimed to determine the reference ranges for automated erythrocyte and reticulocyte parameters in healthy individuals on Sysmex XN 1000 hematology analyzer. Methods One hundred and thirty-three subjects with normal physical examination and complete blood count results within the reference ranges were included in the study. Venous blood samples collected in tubes containing K2-EDTA were analyzed on Sysmex XN-1000. The references intervals for IRF, RBC He, Ret He, LFR, MFR, HFR, Delta He, Micro R, Macro R, Hypo He and Hyper He were determined according to CLSI EP28-A3c. Results The reference ranges of the parameters were estimated with 90% confidence intervals. The reference ranges were 3.4–17% for IRF, 26.9–32.8 pg for Ret-He, 25.2–30.5 pg for RBC-He and 0.5–3.7 pg for delta-He. Gender specific reference ranges were calculated for of Ret-He (male (M): 26.8–32.9 pg, female (F): 23.9–33.6 pg), RBC-He (M: 26.3–30.8 pg, F: 25.3–30.5 pg) and delta-He (M: 0.5–3.7 pg, F: 0.3–3.7 pg). Conclusions The new reticulocyte and erythrocyte parameters may be conveniently used in clinical diagnosis and follow-up of patients, as they offer reliable, automated and cheap results. Each laboratory is recommended to determine its own reference intervals considering the differences like the instrument used and population studied.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,Molecular Biology,Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3