OrbiSIMS depth profiling of semiconductor materials—Useful yield and depth resolution

Author:

Zhou Yundong1ORCID,Franquet Alexis2ORCID,Spampinato Valentina23ORCID,Merkulov Alex2ORCID,Keenan Michael R.4ORCID,van der Heide Paul A. W.2ORCID,Trindade Gustavo F.1ORCID,Vandervorst Wilfried2ORCID,Gilmore Ian S.1ORCID

Affiliation:

1. National Physical Laboratory 1 , Hampton Rd, Teddington TW11 0LW, United Kingdom

2. IMEC 2 , Kapeldreef 75, Leuven 3001, Belgium

3. Dipartimento di Scienze Chimiche, Università degli Studi di Catania 3 , Viale A. Doria 6, Catania 95125, Italy

4. Independent 4 , Georgetown, Texas 78626

Abstract

OrbiSIMS is a secondary ion mass spectrometry method with dual mass analyzers: a time-of-flight (ToF) mass spectrometer for high-speed imaging and an Orbitrap™ for high mass resolving power and mass accuracy. Originally developed for biological imaging, there is now growing interest in the application to semiconductor materials to resolve peak interferences that obfuscate analysis in traditional SIMS depth profiling experiments. We use a new method to calibrate the Orbitrap intensity scale to true counts, which allows comparison of the useful yield and duty cycle with a magnetic sector instrument and a time-of-flight instrument using an Sb implant in the silicon sample. The useful yield of the Orbitrap and magnetic sector instruments (for one detected peak) are similar. However, since the magnetic sector instrument has serial mass detection, its useful yield reduces as more peaks are analyzed. While the ToF instrument has parallel detection, it has a low duty cycle and the useful yield is two orders of magnitude lower for 1000 eV Cs+ sputtering. The depth resolution was also compared from the measurement of the downslope from depth profiles of an Sb delta multilayer. For 1000 eV Cs+ sputtering, the downslopes are 3.9, 2.3, and 2.7 nm/decade for Orbitrap, magnetic sector, and ToF instruments, respectively. Ion trajectory simulation shows that the poorer depth resolution of the OrbiSIMS is in part due to ion beam distortion at low energy.

Funder

The UK National Measurement System

Publisher

American Vacuum Society