Author:
Amatobi Damiana A.,Agunwamba Jonah C.
Abstract
AbstractThis study improves on the conventional SODIS design to make it more effective and increase its acceptability. An improved SODIS was designed to allow polyethylene teraphalate (PET) bottles serving as reactors to be under approximately 97% sunrays’ cover, and with a provision for a heat absorber. The improved SODIS was tested for inactivation of microorganisms by loading it with eight PET bottles filled with water containing 105 to 107 CFU/100 ml of Escherichia coli. The test was conducted simultaneously with a conventional SODIS, consisting of an improvised rooftop arrangement, containing same quantity of water-filled bottles with same concentration of E. coli. The two systems were placed close to each other, and exposed to direct sunlight for seven hours each day, on six different days. Ambient temperature was measured with a general-purpose thermometer. The thermometer was inserted into one bottle on each system to measure (representative) temperature. At hourly time intervals, a bottle was taken out from each system for enumeration of E. coli concentration. Hourly ambient and bottle temperatures were read simultaneously. The improved SODIS achieved a temperature of 4 °C above ambient and 1 °C above the conventional SODIS. In all the experiment days, complete inactivation of E-coli below detectable limit (less than 1 CFU/100 ml) was achieved at the fourth hour of exposure to sunlight by the improved SODIS and sixth hour by the conventional SODIS. The inactivation rates, K, for E. coli were 0.53 and 0.46 for the improved SODIS and the conventional (rooftop) SODIS, respectively.
Publisher
Springer Science and Business Media LLC
Subject
Water Science and Technology
Reference20 articles.
1. Agunwamba JC (2008) Water engineering systems. De-Adroit Innovation, Enugu
2. Amin MT, Nawaz M, Amin MN, Han M (2014) Solar disinfection of Pseudomonas aeruginosa in harvested rainwater: A STEP towards potability of rainwater. PLOS ONE 9(3):e90743
3. Asiimwe JK, Quilty B, Muyanja CK, McGuigan KG (2013) Field comparison of solar water disinfection (SODIS) efficacy between glass and polyethylene terephalate (PET) plastic bottles under sub-Saharan weather conditions. J Water Health 11(4):729–737. https://doi.org/10.2166/wh.2013.197
4. Berman J (2009) WHO: Waterborne disease is world's leading killer. Voice of America. https://www.voanews.com/archive/who-waterborne-disease-worlds-leading-killer. Accessed 10 December 2020
5. Bichi MH, Amatobi DA (2013) Assessment of the quality of water supplied by water vendors to households in Sabon-gari area of Kano, northern Nigeria. Int J Eng Sci (IJES) 2(7):09–17
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献