Axial rod slip at the end-of-construct screw in scoliosis surgery: relevance, occurrence and prevention

Author:

Schlösser T. P.ORCID,Blaauw I.,van der Valk M. R.,van Solinge Guido,Faber C.,Kruyt M. C.

Abstract

Abstract Purpose Despite standardized biomechanical tests for spinal implants, we recently recognized pedicle screw failure to maintain the rod fixated as a clinical concern in scoliosis surgery. This occurrence study investigates the risk and magnitude of axial rod slip (ARS), its relation with technique and preventive measures. Methods Retrospective multicenter review of all primary scoliosis cases (2018–2020) with > 1 year FU from three centers, instrumented with uniplanar screws and 5.5 mm CoCr rods (Mesa 2, Stryker Corporation, Kalamazoo, MI, USA). ARS was defined as > 1 mm change in residual distal rod length from the screw in the lowest instrumented vertebra (LIV) and assessed by two independent observers. Slip distance, direction, relation to distal screw density and time of observation were recorded, as well as the effect of ARS on caudal curve increase. To prevent slip, more recent patients were instrumented with a different end-of-construct screw (Reline, NuVasive Inc. San Diego, CA, USA) and analyzed for comparison. Results ARS risk was 27% (56/205) with a distance of 3.6 ± 2.2 mm, predominantly convex. 42% occurred before 4 months, the rest before 1 year. The caudal curve substantially increased three times more often in patients with ARS. Interobserver reliability was high and slip was in the expected direction. ARS was unrelated to distal screw density. Remarkable variation in ARS rates (53%, 31%, 13%) existed between the centers, while there was no difference in mean screw density (≈1.3 screws/level) or curve correction (≈60%). Revision surgery for ARS was required in 2.9% (6/207). Using the different end-of-construct screw, ARS risk was only 2% (1/56) and no revisions were required. Conclusion This study demonstrates the prevalence of axial rod slip at the end of construct in scoliosis surgery and its clinical relevance. While minimal ARS can be subclinical, ARS should not be mistaken for adding on. The most severe ARS predominantly occurred convex at the high-loaded distal screw when L3 was the LIV. Longer constructs (LIV L3 or L4) have a higher risk of ARS. The minimal risk of ARS with another end-of-construct screw underscores the influence of screw type on ARS occurrence in our series. Further research is essential to refine techniques and enhance patient outcomes.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3