Author:
Lüke Jan Niklas,Reinking Niklas,Dietlein Thomas S.,Haendel Alexander,Enders Philip,Lappas Alexandra
Abstract
Abstract
Purpose
The aim of the underlying study was to present a new surgical method in PreserFlo MicroShunt surgery for glaucoma. A removable polyamide suture was placed into the lumen of the MicroShunt during implantation to prevent early postoperative hypotony.
Methods
Thirty-one patients undergoing stand-alone glaucoma surgery with implantation of a PreserFlo MicroShunt and an intraluminal occlusion were retrospectively reviewed and compared to a control group without occlusion. Inclusion criteria were diagnosis of primary open-angle glaucoma or secondary open-angle glaucoma due to pseudoexfoliation or pigment dispersion. Patients with a history of filtrating glaucoma surgery were excluded.
Results
IOP decreased from 26.9 ± 6.6 to 18.0 ± 9.5 mmHg at the first postoperative day after PreserFlo MicroShunt implantation. Postoperative removal of the occluding suture resulted in a mean IOP reduction in 11.1 ± 7.6 mmHg. Mean visual acuity was 0.43 ± 0.24 logMAR during the first postoperative examination. The interval with the occluding intraluminal suture in place varied from days to 2–3 weeks. Patients were followed up to 1 year.
Conclusion
Implantation of a PreserFlo MicroShunt combined with an intraluminal suture prevented postoperative hypotony in all patients. Mean postoperative pressure was reduced despite the occluding suture in place.
Funder
Universitätsklinikum Köln
Publisher
Springer Science and Business Media LLC
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献