The optimal fluoroscopic views to rule out intra-articular screw penetration during acetabular fracture fixation

Author:

Elmhiregh Aissam,Hantouly Ashraf T.,Alzoubi Osama,George Bivin,Ahmadi Mohsen,Ahmed GhalibORCID

Abstract

Abstract Purpose To determine the ideal view(s) and the minimum number of intraoperative fluoroscopic views required to rule out any intra-articular screw violation in acetabular fractures fixation. Methods This study was conducted using a series of fluoroscopic examinations of pelvic synthetic models with screws positioned in different planes around the acetabulum. Ten screws were placed in the synthetic pelvis models in different planes of the acetabulum. Seven views were taken for each screw. Radiographic images were evaluated by 14 orthopaedic surgeons who were asked to assess joint violation and the view(s) required for assessment. Results The observers’ accuracy rate in identifying joint violation was 82.1% for the anterior part of the anterior column and the superior part of the posterior column, 89.3% for the posterior part of the anterior column and the inferior part of the posterior column, and 92.9% for the quadrilateral plate. The sensitivity was 100% for the anterior and posterior parts of the anterior column and the inferior part of the posterior column, 87.5% for the superior part of the posterior column, and 85.7% for the quadrilateral plate. The specificity was 100% for the quadrilateral plate, 80% for the superior part of the posterior column and the posterior part of the anterior column, 78.6% for the inferior part of the posterior column, and 66.7% for the anterior part of the anterior column. There was a strong overall interobserver and intra-observer agreement with intraclass correlation coefficient (ICC) of 0.709 and 0.86, respectively. Conclusions This study confirms the hypothesis that in a concave surface/joint fixation, such as the acetabulum, the probability of joint violation is unlikely if there is no evidence of it within a single fluoroscopic view. In acetabulum fracture fixation with a screw violating the joint, the screw’s presence was evident within the joint space in all fluoroscopic views. However, the absence of joint violation in one fluoroscopic view was adequate to rule out joint penetration.

Funder

Hamad Medical Corporation

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3