Perfusion assessment by fluorescence time curves in esophagectomy with gastric conduit reconstruction: a prospective clinical study

Author:

Joosten J. J.ORCID,Slooter M. D.,van den Elzen R. M.,Bloemen P. R.,Gisbertz S. S.,Eshuis W. J.,Daams F.,de Bruin D. M.,van Berge Henegouwen M. I.

Abstract

Abstract Background Intraoperative perfusion assessment with indocyanine green fluorescence angiography (ICG-FA) may reduce postoperative anastomotic leakage rates after esophagectomy with gastric conduit reconstruction. This study evaluated quantitative parameters derived from fluorescence time curves to determine a threshold for adequate perfusion and predict postoperative anastomotic complications. Methods This prospective cohort study included consecutive patients who underwent FA-guided esophagectomy with gastric conduit reconstruction between August 2020 and February 2022. After intravenous bolus injection of 0.05-mg/kg ICG, fluorescence intensity was registered over time by PINPOINT camera (Stryker, USA). Fluorescent angiograms were quantitatively analyzed at a region of interest of 1 cm diameter at the anastomotic site on the conduit using tailor-made software. Extracted fluorescence parameters were both inflow (T0, Tmax, Fmax, slope, Time-to-peak) as outflow parameters (T90% and T80%). Anastomotic complications including anastomotic leakage (AL) and strictures were documented. Fluorescence parameters in patients with AL were compared to those without AL. Results One hundred and three patients (81 male, 65.7 ± 9.9 years) were included, the majority of whom (88%) underwent an Ivor Lewis procedure. AL occurred in 19% of patients (n = 20/103). Both time to peak as Tmax were significantly longer for the AL group in comparison to the non-AL group (39 s vs. 26 s, p = 0.04 and 65 vs. 51 s, p = 0.03, respectively). Slope was 1.0 (IQR 0.3–2.5) and 1.7 (IQR 1.0–3.0) for the AL and non-AL group (p = 0.11). Outflow was longer in the AL group, although not significantly, T90% 30 versus 15 s, respectively, p = 0.20). Univariate analysis indicated that Tmax might be predictive for AL, although not reaching significance (p = 0.10, area under the curve 0.71) and a cut-off value of 97 s was derived, with a specificity of 92%. Conclusion This study demonstrated quantitative parameters and identified a fluorescent threshold which could be used for intraoperative decision-making and to identify high-risk patients for anastomotic leakage during esophagectomy with gastric conduit reconstruction. A significant predictive value remains to be determined in future studies.

Publisher

Springer Science and Business Media LLC

Subject

Surgery

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3