MRI-based static and functional assessment of complex hip deformities in comparison with CT: a validation study

Author:

Blum SophiaORCID,Franken Lea,Hartmann Albrecht,Thielemann Falk,Plodeck Verena,Danowski Dirk,Kühn Jens-PeterORCID,Hoffmann Ralf-ThorstenORCID,Günther Klaus-Peter,Goronzy Jens

Abstract

Abstract Objective This study aimed at investigating the agreement between predefined quantitative parameters of hip morphology derived from magnetic resonance imaging (MRI) and virtual range of motion (ROM) analysis using computed tomography (CT) as standard of reference. Methods Twenty patients (13 females, 7 males, 16–59 years) with hip deformities underwent MRI prior to surgery. Clockwise alpha angle, femoral head and neck diameter, collum caput diaphysis angle, femoral torsion, center-edge angles, acetabular coverage of the femoral head, sourcil angle, and acetabular anteversion were measured. Additionally, tern single and combined movements were simulated using a motion analysis program. The MRI findings were compared with the corresponding results obtained by CT. Correlation of MRI with CT was assessed using different statistical methods (intraclass correlation coefficient, Bland–Altmann plot, two one-sided t test), and linear regression analysis was performed. Results The results showed near-perfect intraclass correlation coefficients (ICCs) for anteversion (0.95), acetabular sector angles (0.98–0.99), sourcil angle (0.95), and acetabular coverage (anterior 0.96, posterior 0.99). Intermethod correlation for femoral parameters showed almost perfect agreement except for the alpha angle (0.73–0.97). No significant proportional bias was detected for traditional acetabular and femoral parameters. ROM analysis was performed for 370 movements in 37 hips. For 78.4% (290/370) of the movements analysed, neither CT nor MRI detected impingement across the physiological ROM. For 18.6% (69/370) of the movements, impingement was detected by both CT and MRI, while 2.2% (8/370) of the movements with impingement in CT showed no impingement in MRI, and 0.8% (3/370) of the movements with impingement in MRI had no corresponding result in CT. Conclusion Finally, it was concluded that MRI-based assessment of hip morphology and virtual ROM analysis is feasible and can be performed with good intermethod agreement in comparison to the gold standard (CT). Therefore, MRI appears to be substantially equivalent to CT for use in virtual ROM analysis and so may reasonably be used in place of CT for this purpose.

Publisher

Springer Science and Business Media LLC

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology,Biophysics

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3