Reliability of assessing the coronal curvature of children with scoliosis by using ultrasound images

Author:

Chen Wei1,Lou Edmond H. M.23,Zhang Phoebe Q.3,Le Lawrence H.4,Hill Doug23

Affiliation:

1. Department of Biomedical Engineering, University of Alberta, Edmonton, AB Canada

2. Department of Surgery, Glenrose Rehabilitation Research Centre, University of Alberta, 10105-112 Ave, T5G 0H1, Edmonton, AB Canada

3. Alberta Health Services–Glenrose Rehabilitation Hospital, Edmonton, AB Canada

4. Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB Canada

Abstract

Purpose To investigate the intra- and inter-observer reliability of the coronal curvature asymmetry of children with adolescent idiopathic scoliosis (AIS) using the center of lamina (COL) method on ultrasound (US) images. Methods A cadaver spinal column phantom which was manipulated to present 30 scoliotic curves of varying severity of scoliotic deformities was scanned using both the US and laser scanner (LS) systems. Three observers of varying experience and skill measured the coronal curvature using the Cobb method on the LS images and the COL method on the US images. All of the measurements were performed twice, with a 1-week interval to reduce memory bias. The intra-class correlation coefficient (ICC), the mean absolute differences (MAD), and the error index (EI) were calculated to determine the agreement on selecting the end vertebrae. In addition, five AIS subjects were scanned using the US system. One observer measured the coronal curvature on the US images twice, and the measurements were compared with the Cobb angle reported in the clinical records. Results In the phantom study, the COL method showed high intra- and inter-observer reliabilities, with all ICC values >0.88. The maximum MAD of the COL measurements between different sessions among all observers was <4.1°. The EI values of the US method had similar end-vertebra selections as the LS method. The results of the pilot study showed a high intra-reliability for the US measurements. The measured difference between the Cobb and COL methods was 0.7° ± 0.5°. Conclusions The COL method using US images appears to be a very reliable method for measuring the coronal curvature in AIS without the need to expose the patient to radiation.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Pediatrics, Perinatology and Child Health