CT venography correlate of transverse sinus stenosis and venous transstenotic pressure gradient in unilateral pulsatile tinnitus patients with sigmoid sinus wall anomalies

Author:

Zhao Pengfei,Ding Heyu,Lv Han,Li Xiaoshuai,Qiu Xiaoyu,Zeng Rong,Wang Guopeng,Wei Jian,Jin Long,Yang Zhenghan,Gong Shusheng,Wang ZhenchangORCID

Abstract

Abstract Objectives To investigate the correlation between transverse sinus stenosis (TSS) and transstenotic pressure gradient (TPG) in unilateral pulsatile tinnitus (PT) patients with sigmoid sinus wall anomalies (SSWA). Methods Fifty-seven patients with unilateral venous PT were retrospectively included. All of them underwent CT venography and catheter manometry, accompanied with SSWA. The degree, length, shape (intrinsic/extrinsic/dysplasia), location (proximal/middle/distal, referring to the relative position of TSS and the Labbé vein junction) of TSS, the types of SSWA (dehiscence/diverticulum), and the degree of transverse sinus outflow laterality were assessed, and the correlations with ipsilesional TPG were analyzed. Results The mean value of ipsilesional TPG was 7.61 ± 0.52 mmHg. The degree and length of ipsilesional TSS were positively correlated with TPG (p < 0.001, p’ < 0.001), respectively. TPG was significantly larger in patients with contralateral transverse sinus dysplasia than those without (p = 0.023) and significantly smaller in patients with ipsilesional sigmoid sinus diverticulum than those with isolated dehiscence (p = 0.001). No statistical difference in TPG was shown between ipsilesional TSSs of different shapes or locations (p > 0.05). No correlation was noted between the degree of ipsilesional transverse sinus outflow laterality and TPG (p = 0.051). Stepwise linear regression indicated that the degree (β = 9.207, 95% CI = 3.558–14.856), length (β = 0.122, 95% CI = 0.025–0.220) of ipsilesional TSS, and contralateral transverse sinus dysplasia (β = 1.875, 95% CI = 0.220–3.530) were significantly correlated with TPG (R2 = 0.471). Conclusions The degree, length of ipsilesional TSS, and contralateral transverse sinus dysplasia may be used to predict TPG in unilateral PT patients with SSWA. Key Points CT venography may act as a screening tool to help low-probability unilateral pulsatile tinnitus (PT) patients with sigmoid sinus wall anomalies (SSWA) avoid invasive catheter manometry. The degree and length of ipsilesional transverse sinus stenosis (TSS) are positively correlated with transtenotic pressure gradient (TPG) in unilateral PT patients with SSWA. Ipsilesional TPG is larger in unilateral PT patients with contralateral transverse sinus dysplasia than those without and is smaller in unilateral PT patients with sigmoid sinus diverticulum than those with isolated dehiscence.

Funder

National Natural Science Foundation of China

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

全球学者库

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"全球学者库"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前全球学者库共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2023 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3