The first-generation anatomical medial meniscus prosthesis led to unsatisfactory results: a first-in-human study

Author:

van Tienen T. G.ORCID,van Minnen B.,Defoort K. C.,Emans P. J.,van de Groes S. A. W.,Verdonschot N.,Jutten L. M.,Pikaart R. W. E.,Heesterbeek P. J. C.

Abstract

Abstract Purpose The purpose of this first-in-human study was to evaluate the effect of a polycarbonate anatomical meniscus prosthesis system, including the surgical procedure, on knee pain and describe potential adverse events in patients with post-meniscectomy pain syndrome. Methods Eleven patients with post-meniscectomy pain syndrome and limited underlying cartilage damage were enrolled in the study. Five received a medial polycarbonate urethane meniscus prosthesis which was clicked onto 2 titanium screws fixated at the native horn attachments on the tibia. The KOOS score was planned to be collected at baseline and at 3, 6, 12 and 24 months following the intervention including radiographs at 6, 12 and 24 months. MRI scans were repeated after 12 and 24 months. Results The surgical technique to select an appropriately sized implant and correct positioning of the fixation screws and meniscus prosthesis onto the tibia was demonstrated to be feasible and reproducible. Inclusion stopped after 5 patients because of serious adverse device-related events. All patients reported knee joint stiffness and slight effusion in their knee at 6 months follow-up. In 3 patients the implant was removed because of implant failure and in 1 patient the implant was removed because of persistent pain and extension limitation. In none of the patients did the KOOS score improve in the first 6 months after surgery. However, in the patient who still has the implant in situ, PROMs started to improve 1 year after surgery and this improvement continued through 2 years of follow-up. The KOOS Pain, symptoms and ADL were close to the maximal 100 points. KOOS QoL and sport did improve but remained suboptimal. Conclusion This first version of the meniscus prosthesis led to impaired knee function and failed in four out of five patients. The patients where the prosthesis was removed were salvable and the PROMs returned to pre-study levels. The results in the patient where the device is still in place are promising. Level of evidence Level II.

Funder

ATRO Medical BV

Publisher

Springer Science and Business Media LLC

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3