Abstract
Abstract
Purpose
In this study, we developed in-house software to evaluate the effect of the lead block (LB)-inserted spacer on the mandibular dose in interstitial brachytherapy (ISBT) for tongue cancer. In addition, an inverse planning algorithm for LB attenuation was developed, and its performance in mandibular dose reduction was evaluated.
Methods
Treatment plans of 30 patients with tongue cancer treated with ISBT were evaluated. The prescribed dose was 54 Gy/9 fractions. An in-house software was developed to calculate the dose distribution based on the American Association of Physicists in Medicine (AAPM) Task Group No.43 (TG-43) formalism. The mandibular dose was calculated with consideration of the LB attenuation. The attenuation coefficient of the lead was computed using the PHITS Monte Carlo simulation. The software further optimized the treatment plans using an attraction–repulsion model (ARM) to account for the LB attenuation.
Results
Compared to the calculation in water, the D2 cc of the mandible changed by − 2.4 ± 2.3 Gy (range, − 8.6 to − 0.1 Gy) when the LB attenuation was considered. The ARM optimization with consideration of the LB resulted in a − 2.4 ± 2.4 Gy (range, − 8.2 to 0.0 Gy) change in mandibular D2 cc.
Conclusions
This study enabled the evaluation of the dose distribution with consideration of the LB attenuation. The ARM optimization with lead attenuation further reduced the mandibular dose.
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献