Abstract

OBJECTIVE This study evaluated the association of time in range (TIR) of 70–180 mg/dL (3.9–10 mmol/L) with the development or progression of retinopathy and development of microalbuminuria using the Diabetes Control and Complications Trial (DCCT) data set in order to validate the use of TIR as an outcome measure for clinical trials. RESEARCH DESIGN AND METHODS In the DCCT, blood glucose concentrations were measured at a central laboratory from seven fingerstick samples (seven-point testing: pre- and 90-min postmeals and at bedtime) collected during 1 day every 3 months. Retinopathy progression was assessed every 6 months and urinary microalbuminuria development every 12 months. Proportional hazards models were used to assess the association of TIR and other glycemic metrics, computed from the seven-point fingerstick data, with the rate of development of microvascular complications. RESULTS Mean TIR of seven-point profiles for the 1,440 participants was 41 ± 16%. The hazard rate of development of retinopathy progression was increased by 64% (95% CI 51–78), and development of the microalbuminuria outcome was increased by 40% (95% CI 25–56), for each 10 percentage points lower TIR (P < 0.001 for each). Results were similar for mean glucose and hyperglycemia metrics. CONCLUSIONS Based on these results, a compelling case can be made that TIR is strongly associated with the risk of microvascular complications and should be an acceptable end point for clinical trials. Although hemoglobin A1c remains a valuable outcome metric in clinical trials, TIR and other glycemic metrics—especially when measured with continuous glucose monitoring—add value as outcome measures in many studies.

Funder

Jaeb Center for Health Research Foundation

Publisher

American Diabetes Association

Subject

Advanced and Specialized Nursing,Endocrinology, Diabetes and Metabolism,Internal Medicine

Reference26 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3